INDICATION FOR STUDY:         The patient has had a previous study in XXXXXXX.  This film should be obtained and sent to this department for comparison with the current study.

TECHNIQUE:          CC and MLO views of each breast were obtained along with CAD evaluation on the digital mammogram machine and the CAD evaluation was reviewed.

FINDINGS:               It should be noted that the patient presents with no complaints.

The dominant finding is fatty replacement with only a very minimal amount of residual heterogeneous breast tissue remaining in either breast.

No malignant appearing calcifications are seen.  No mass is identified.  The subcutaneous tissue and vascularity is normal.  The skin and nipples are normal.

IMPRESSION:

BI-RADS Clinical Assessment Category 2:  Benign finding.


Thank you for the referral.
XXXXXXXXX, M.D.